·. Uses |
|
| |
Fillers, seals, fix and isolates from cold, hotness and sounds.
Can be use as an isolator protector of electrical conductions and water. Can be use for the hollow fillers between elements, fixations of tiles, etc.
|
|
 |
 |
·. Surface preparation |
|
| |
Adhere all types of surfaces, except polypropylene and polyethylene. |
|
 |
 |
·. Instructions for use |
|
| |
Shake energetically the aerosol before applying.
It’s convenient to damp the surface to improve the adherence, reticulation and the inured of the foam EXPANPLUS.
The surfaces must be clean of dust and grease.
Twist the gun in the jar up side down and adjust the screw of dosage. Eliminate the remaining fresh foam and clean it with our EXPANPLUS L. cleansing.
Work temperature: of 10ºC to 30ºC.
|
|
 |
 |
·. Consumption |
|
| |
Expand 2-3 times its volume. Filled to a 40% of the volume of hallows. The lack of air and humidity may cause delayed on the expansion of the foam. |
|
 |
 |
·. Colours |
|
| |
Yellow.
|
|
 |
 |
·. Packing and storing |
|
| |
In aerosols application by gun of 750ml, Perfect preservation in its original packaging for 12 months after its date of production, reflected at the bottom of the package. |
|
 |
 |
·. Hygiene and safety |
|
| |
All the relevant indications and use for the packaging of aerosol products.
|
|
 |
 |
·. Specification |
|
| |
Base: Polyurethane, Stable foam with humid inured system.
Skin formation (20ºC and 65% H.R): 10 minutes
Dry time: Free of dust after 20-25 min. Inured 3h/5cm.
Foam Yield: 1000ml yield 30-40 litre of foam.
Contraction: None
Reticulation: 80% in closed cells
Specific weight: 21/25 kg/m3
Temperature resistant: from 40ºC to 100ºC
Foam characteristics: Thixotropic
Classification of fire reaction: B-2-B3 (DIN 4102 part 2)
Insulating factor: 0,032 kcal/ mh ºc (lambda)
Maximum tension: CA 15N/cm3
Permeability to vapour: 70g/m2 /24h. (DIN 53429)
|
|
 |
| |
NOTES:
- These technical specifications, as the other recommendations and technical information, are useful only for the description of the product characteristics, instructions of use and its uses. Data information are based in our technical knowledge obtained in bibliography, laboratory essays and by our own practice.
- Consumption data and dosages which appears in these specifications are based in our own experience, so they can vary due to different conditions in the building place. Real consumption and dosages have to be determined in the building place through previous essays and they are customer responsibility.
- For further information, our Applied Construction Chemistry Department is at your disposal.
- Other uses witch do not fit with the specifications are not from our responsibility.
- We give guarantee in case of manufacturing quality problems; so excludes further reclamations and our only responsibility is to return the value of the product.
- Patents and rights must be taken into account.
- The present file losses its validity with the launching of new edition.
|
|